A temperature and humidity transducer designed to fit any environment with selectable temperature ranges and sensor options.

Sensor unit extended Temperature and Humidity Transmitter THT-V2 Series

Temperature / humidity converter THT-V2 series is a 2-wire current output type temperature / humidity converter with an extended sensor.

The temperature range can be selected. The sensor can also be selected from various types, so it can be used to measure temperature and humidity at any location. In addition, the converter is small and light, so it is suitable for integration.

Features

  • The lightweight, compact design makes it ideal for integration into equipment and facilities.
  • 4-20mA 2×2-wire connection type

Specification

ModelTHT-V2
PowerDC10 ~ 27V
Current consumption4~20mA
Storage environment range-10~60℃、> 90%rh (no condensation)
Measurement range10 to 60℃, 95%rh or less
Humidity sensorPolymer humidity sensor
Temperature sensorPt100Ω
Accuracy±3%rh (at 25℃ 35 to 85%rh)
±0.5℃ (at 0 to 50℃)
Cable length1.5m
Ootput4 to 20mA

Application Examples

Extended Multi-Purpose Sensor Temperature and Humidity Converter

The THT-V2 series of temperature and humidity transducers feature an extended sensor design with a two-wire current output. The temperature range is selectable to suit specific requirements. Additionally, its compact and lightweight construction makes it ideal for integration into various types of industrial machinery

Temperature and Humidity Management for Greenhouses and Plant Factories

For temperature and humidity management of food display cases

For temperature and humidity management in offices, factories, and clean rooms.

For air conditioning control in the server room.

For integration into various industrial machines.

Precautions

  • Please avoid condensation and exposure to moisture.
  • Do not use the device in the presence of the following gases and atmospheres:
    • Salty conditions
    • Inorganic gases such as sulfur dioxide, chlorine, ammonia, etc.
    • Organic gases such as alcohols, glycols, aldehydes, etc.
  • When storing, keep the device in an environment between 10°C and 40°C with a relative humidity of 60% or less.
  • Before powering on, ensure that the wiring is correct and there are no mistakes.
  • Avoid using the device in environments with excessive external noise, as it may affect signal integrity.

How to Use

Instructions for Use
  1. Choose a location and install the sensor.
  2. Secure the converter unit with the four screws.
  3. Remove the cap and connect the signal wires.
  4. Power on the device.
Conversion Part Shape
Mounting Dimensions
Wiring